MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-015-2369-5

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2015

The effect of local bone density on mechanical failure after internal fixation of pertrochanteric fractures.

Li Changhua, Xie Bingju, Chen Shanxi, Lin Guangmao, Yang Guojing, Zhang Lei

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The aim of this prospective study was to investigate the effect of local hip bone density on mechanical failure after fixation of pertrochanteric fractures and to establish possible risk factors for the failures.

MATERIALS AND

METHODS

A total of 136 consecutive patients presenting a closed unilateral pertrochanteric fracture were enrolled. The patients were treated with a sliding hip screw or an intramedullary nail. Dual energy X-ray absorptiometry measurements for bone density of the contralateral hip were made within 4 weeks postoperatively. Follow-up evaluations on the standard radiographs were documented for any mechanical failure including loss of reduction, screw or blade cut-out, lateral migration of the screw or blade, and implant breakage. Secondary outcomes were also recorded including patient characteristics and fixation construct variables as possible predictors for mechanical failure.

RESULTS

At a minimum of 2 years of follow-up, 38 patients were reported with mechanical failure at an estimated risk of 27.9 %. The local bone density measurements for the study population showed no difference between patients with (0.710 g/cm(2)) and without (0.726 g/cm(2)) mechanical failure (P = 0.180). We also observed no significant correlation between local bone density and failure in patients with good fracture reduction (P = 0.862). The multivariate regression analysis identified fracture type (P < 0.001) and quality of fracture reduction (P < 0.001) as being independent predictors for mechanical failure, whereas local bone density was not (P = 0.658).

CONCLUSIONS

Local hip bone density does not appear to have a significant influence on mechanical failure after internal fixation of pertrochanteric fractures. Stable fractures and fractures with good reduction are expected to obtain satisfactory outcomes.

Для цитирования: Li Changhua, Xie Bingju, Chen Shanxi, Lin Guangmao, Yang Guojing, Zhang Lei. The effect of local bone density on mechanical failure after internal fixation of pertrochanteric fractures.. Archives of orthopaedic and trauma surgery. 2015. DOI: 10.1007/s00402-015-2369-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.