MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2024.111317

Медицинская библиотека · Injury · 2024

Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A biomechanical analysis and clinical results.

Xian Hang, Cheng Weike, Xie Wei, Wang Lei, Luo Deqing, Liu Hui, Lian Kejian, Lin Dasheng

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze the effects of the angle between dynamic hip screw (DHS) and anti-rotation screw (AS) on vertically oriented femoral neck fractures (VOFNFs) and investigate the clinical results of them.

METHODS

Eighteen synthetic femurs were simulated and divided into 3 groups. The angle between DHS and AS in anteroposterior-view was marked as α, and in lateral-view was marked as β, thus the total angle (TA) was defined as the summation of α and β. The groups were categorized as group A (TA ≤ 5°), B (5° < TA ≤ 10°), and C (TA > 10°), respectively. All samples were tested under incremental, cyclical loading, and loading to failure. In clinic, 80 consecutive VOFNFs in 78 patients were treated with DHS plus AS. The patients were divided into 2 groups, including 48 fractures in parallel group (TA ≤10°) and 32 in angular group (TA >10°).

RESULTS

Group A and B survived during incremental and cyclical loading and endured longer than group C. Axial stiffness and failure loads were not different between group A and B, and greater than group C. Fracture gaps compressive stress was highest in group A, followed by group B and C. Forty-one fractures in parallel group and 23 in angular group healed at final follow-up. Nonunion and osteonecrosis occurred in 3 and 4 of parallel group, and 4 and 5 of angular group.

CONCLUSION

The construction with TA ≤10° between DHS and AS showed superior biomechanical performance and clinical results than those with TA >10°.

Для цитирования: Xian Hang, Cheng Weike, Xie Wei, Wang Lei, Luo Deqing, Liu Hui, Lian Kejian, Lin Dasheng. Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A biomechanical analysis and clinical results.. Injury. 2024. DOI: 10.1016/j.injury.2024.111317.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.