MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1754-9485.13171

Медицинская библиотека · Journal of medical imaging and radiation oncology · 2021

Assessment of short-term response and review of technique of ultrasound-guided percutaneous A1 pulley release for the treatment of trigger finger.

White Roland Z, Sampson Matthew J

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Ultrasound-guided percutaneous first annular pulley (A1) release is a non-surgical management for the treatment of trigger finger, also known as stenosing tenosynovitis. Trigger finger occurs secondary to inflammation and retinacular sheath hypertrophy with subsequent restriction of the flexor tendons. Trigger finger can have a marked functional impact, with current conservative measures including steroids and/or splinting, and surgical therapy involving open release.

METHODS

A population of 20 adult patients with ultrasound proven trigger finger underwent percutaneous release with refined technique. Patients with additional ultrasound proven tenosynovitis received steroid injection.

RESULTS

Of the 20 cases, 18 cases involved the fingers, 2 cases involved the thumb and 14 cases had additional tenosynovitis. All procedures involving the fingers were well tolerated with initial symptomatic and functional relief. At 1-week post-intervention, 2 finger cases without concurrent steroid injection represented with pain but not triggering. Cases which did not receive concurrent steroid injection described post-procedural pain requiring oral analgesia. One case involving the thumb was complicated by no relief with a mild radial digital nerve neuropraxia, with near complete resolution at 6 weeks. The second thumb case reported only partial relief of triggering.

CONCLUSION

US-guided percutaneous release of the A1 pulley is an effective procedure in achieving at least short-term resolution of trigger finger. It is best reserved for fingers due to the challenging anatomy of the thumb.

Для цитирования: White Roland Z, Sampson Matthew J. Assessment of short-term response and review of technique of ultrasound-guided percutaneous A1 pulley release for the treatment of trigger finger.. Journal of medical imaging and radiation oncology. 2021. DOI: 10.1111/1754-9485.13171.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.