MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.70117

Медицинская библиотека · Veterinary surgery : VS · 2026

Locked plate versus modified clamp-rod internal fixation for feline corpus ilium fractures: A comparative clinical study.

Saylak Nahit, Yayla Sadık, Altan Semih, Ersöz-Kanay Berna, Çatalkaya Emine

СтатьяСравнительное исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the applicability and clinical effectiveness of a modified clamp-rod internal fixation (M-CRIF) system compared with conventional locking plate osteosynthesis in the treatment of feline corpus ilium fractures.

STUDY

DESIGN

Prospective, controlled clinical study.

ANIMALS: Thirty-six client-owned cats with corpus ilium fractures.

METHODS

Cats were randomly assigned to two groups: Group I (M-CRIF, n = 18) and Group II (locking plate, n = 18). All fractures were stabilized with a lateral approach. Radiographic healing, sacral index (SI), and complications were assessed at postoperative days 21, 45, 60, and 120. Long-term outcomes were assessed using owner questionnaires addressing mobility and defecation.

RESULTS

Fracture union was achieved in all cats. Healing scores increased over time in both groups (p < .05). At day 45, Group I showed higher healing scores than Group II (p = .002). Sacral index narrowing was lower in Group I (p = .005). Implant-related complications occurred in 22.2% (4/18) of cats in the plate group, including screw loosening and one revision surgery, whereas no screw loosening was observed in the M-CRIF group. Preoperative neurological deficits were present in 22.2% of cats, decreasing to 5.5% postoperatively. Owner questionnaires indicated satisfactory mobility, although some discrepancies with clinical and radiographic findings were observed.

CONCLUSION

The M-CRIF system provided greater stability, fewer complications, and better preservation of the pelvic canal than locking plates.

CLINICAL SIGNIFICANCE: This study is the first clinical evaluation of the M-CRIF system in feline ilial fractures and demonstrates favorable outcomes, supporting its use as a reliable alternative to conventional plating.

Для цитирования: Saylak Nahit, Yayla Sadık, Altan Semih, Ersöz-Kanay Berna, Çatalkaya Emine. Locked plate versus modified clamp-rod internal fixation for feline corpus ilium fractures: A comparative clinical study.. Veterinary surgery : VS. 2026. DOI: 10.1111/vsu.70117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.