DOI 10.1016/j.jhsa.2026.01.032
Simple Excision of Proximal Scaphoid Nonunion: A Viable Option When the Scapholunate Ligament Is Intact.
Аннотация
PURPOSE: Because of the biological, anatomical, and biomechanical characteristics of the scaphoid, treating some proximal pole nonunions remains challenging. The location of the nonunion (proximal or distal to the dorsal apex) may influence its natural history. Based on this concept, patients with a proximal pole nonunion located proximal to the dorsal apex and maintaining an intact insertion of the dorsal scapholunate ligament in the distal fragment of the scaphoid may benefit from simple excision of the proximal pole. This study evaluated the clinical and functional outcomes of this treatment approach.
METHODS
A retrospective review was conducted on 11 patients who underwent simple excision of the proximal pole fragment as treatment for proximal pole scaphoid nonunion in which the scapholunate interosseous ligament remained attached to the distal fragment. Postoperative outcomes included pain, range of motion, grip strength, and patient-reported outcome measures, including the Patient-Rated Wrist Evaluation, Patient-Specific Functional Scale, and EQ-5D. Patient satisfaction and return-to-work rates were also analyzed.
RESULTS
Postoperative pain, Patient-Rated Wrist Evaluation, Patient-Specific Functional Scale, and EQ-5D scores improved after surgery. Ten of 11 patients returned to their previous occupational activities. Four patients reported dorsoradial discomfort, but only one underwent surgical revision for radial styloidectomy. No radiological progression to a scaphoid nonunion advanced collapse pattern or other complications were observed.
CONCLUSIONS
These findings support that proximal pole simple excision is a viable and relatively simple treatment for a subset of proximal pole scaphoid nonunion in which the proximal fragment is nonviable and a competent dorsal scapholunate ligament remains inserted in the distal fragment.
TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.