MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12200/j.issn.1003-0034.2023.11.002

Медицинская библиотека · Zhongguo gu shang = China journal of orthopaedics and traumatology · 2023

[Clinical application study of multiple small-diameter drilling combined with extracorporeal shock wave therapy (ESWT) under C-arm positioning in the treatment of early femoral head necrosis].

Liu Hai-Jun, Wang Qian-Yuan, Niu Cun-Liang, Wang Geng-Shen, Huang Guo-Yuan

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the therapeutic effect of multiple small diameter drilling combined with extracorporeal shock wave therapy (ESWT) under C-arm X-raylocalization in patients with early osteonecrosis of the femoral head (ONFH).

METHODS

A total of 106 cases of early ONFH patients admitted from May 2015 to May 2017 were retrospectively selected as the study subjects. According to different treatment methods, the patients were divided into observation group and control group, 53 cases in each group. The observation group was treated with multiple small-diameter drilling combined with ESWT under C-arm positioning in the observation group, including 41 males and 12 females with an age of (45.85±6.01) years old (22 to 70 years old);and the control group was treated with ESWT, including 34 males and 19 females with an age of (45.12±5.83) years old(20 to 68 years old) in the control group. The modified Harris hip scores(mHHS), visual analog scale(VAS), hip flexion range, hip abduction and adduction range, ONFH area ratio and clinical efficacy were compared between twe groups before and after treatment. Kaplan-Meier method was used to draw a survival curve to compare the femoral head survival rate between two groups during the 3-year follow-up period after treatment.

RESULTS

There were no complications such as poor wound healing and infection. All of 106 patients were followed up for 28 to 36 months with an average of (31.06±4.28) months. MHHS score, hip flexion range and hip abduction and adduction range in the observation group were increased from (63.85±5.42) scores, (23.79±2.21) °, (32.40±4.19) ° before treatment to (85.51±5.69) scores, (34.65±2.73)°, (43.32±5.71)° at 2 years after treatment, respectively(P<0.05). The above indicators in the control group increased from (64.73±5.64)°, (23.82±2.18)°, (32.45±4.13)° before treatment to (81.65±5.48) scores, (32.79±2.87)°, (39.75±5.68)°at two years after treatment, respectively(P<0.05). VAS score and ONFH area ratio in the observation group decreased from (5.76±1.41) scores and (35.07±4.96)% before treatment to (3.39±1.02) scores and (22.04±3.23)% at 2 years after treatment, respectively(P<0.05). The above indicatiors in control group decreased from (5.73±1.45) scores and (35.24±5.18)% before treatment to (4.43±1.21) scores and (28.32±3.76)% at 2 years after treatment, respectively(P<0.05), and the improvement in the observation group was significantly higher than that in the control group(P<0.05). At 3 years after treatment, the femoral head survival rate in the observation group was higher than that in the control group (P<0.05).

CONCLUSION

Multiple small diameter drilling combined with ESWT under C-arm positioning can significantly improve the clinical symptoms of patients with early ONFH, relieve pain and improve clinical efficacy.

Для цитирования: Liu Hai-Jun, Wang Qian-Yuan, Niu Cun-Liang, Wang Geng-Shen, Huang Guo-Yuan. [Clinical application study of multiple small-diameter drilling combined with extracorporeal shock wave therapy (ESWT) under C-arm positioning in the treatment of early femoral head necrosis].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2023. DOI: 10.12200/j.issn.1003-0034.2023.11.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.