Second-Generation Ceramic First Metatarsophalangeal Joint Replacement for Hallux Rigidus.
Аннотация
BACKGROUND
Ceramic first metatarsophalangeal (MP) joint replacement has been reported for treatment of hallux rigidus, but there are no published mid- or long-term studies available. We present our midterm results using a second-generation ceramic first MP joint implant.
METHODS
A retrospective review of clinical data and radiographs was performed for 31 feet (24 women; mean age at surgery, 55 ± 6 years) who had first MP joint replacement with a second-generation ceramic prosthesis (primary, 29 feet; revision, 2 feet). Mean follow-up was 81 ± 27 months after surgery
RESULTS
Mean first MP passive range of motion was 32 ± 17 degrees (dorsi- and plantarflexion). Mean AOFAS score was 72 ± 19 points and Foot Function Index was 27 ± 26 points (all 31 feet). Clinical rating for 29 feet that had surgery as a primary procedure was excellent in 5 feet (17%), good in 8 feet (28%), fair in 3 feet (10%), and poor in 13 feet (45%). Patients were satisfied with the outcome in 24 feet (77%). Follow-up radiographs showed that radiolucency, change in angulation, sinkage, and malalignment of the metatarsal or proximal phalanx components were common. Complications included 1 superficial wound infection, and revision was performed in 5 feet (16%) because of loosening, sinkage, subluxation, pain, or fractured prosthesis. Implant survival was 92% at 5 years, 85% at 7 years, and 68% at 9 years.
CONCLUSION
The results of second-generation ceramic first MP joint replacement in our series demonstrated poor clinical and radiological results with a high revision rate.
LEVEL OF EVIDENCE: Level IV, case series.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.