Successful Treatment of Lumbar Radicular Pain with Selective Nerve Root Injection Using a Racz Catheter: A Case Report.

Park Donghwi, Chang Min Cheol

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: Lumbar transforaminal selective nerve root injection (SNRI) is effective for controlling radicular pain. However, when a patient occasionally experiences severe foraminal stenosis, osteophytes cover the outside opening of the neural foramen, preventing clinicians from inserting a needle tip within the neural foramen.

PATIENTS AND

METHODS

An 81-year-old man complained of left L5 radicular pain (left thigh and calf) due to severe left L5-S1 foraminal stenosis. After failure of conventional transforaminal SNRI in the left L5 due to severe degenerative change in the lumbar spine, SNRI was performed using a Racz catheter. After inserting a 16-gauge cannula via the sacral hiatus, the Racz catheter was inserted. The tip of the catheter was positioned near the left L5 nerve root. After confirming the location of the needle tip using a contrast dye, 20 mg (40 mg/mL) of triamcinolone with 0.5 mL of 1% lidocaine and 2 mL of normal saline was injected.

RESULTS

Immediately after the procedure, the patient's pain completely disappeared. During the 1- and 2-month follow-ups, the patient reported only slight pain in the thigh and calf.

CONCLUSION

When it is not possible to perform a conventional transforaminal SNRI, SNRI using a Racz catheter can be an effective treatment option for controlling lumbar radicular pain.

Для цитирования: Park Donghwi, Chang Min Cheol. Successful Treatment of Lumbar Radicular Pain with Selective Nerve Root Injection Using a Racz Catheter: A Case Report.. Journal of pain research. 2020. DOI: 10.2147/jpr.s251186.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.