MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.22681

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2014

Temporary inductions of matrix metalloprotease-3 (MMP-3) expression and cell apoptosis are associated with tendon degeneration or rupture after corticosteroid injection.

Muto Tomoyuki, Kokubu Takeshi, Mifune Yutaka, Inui Atsuyuki, Harada Yoshifumi, Yoshifumi, Takase Fumiaki, Kuroda Ryosuke, Kurosaka Masahiro

СтатьяПеревод в очереди

Аннотация

Corticosteroid injections are widely used to treat enthesopathy and tendinitis, but are also associated with possible side effects, such as tendon degeneration or rupture. However, the mechanism of tendon degeneration or rupture after corticosteroid injection remains controversial. The purpose of this study was to reveal the mechanism of tendon degeneration or rupture after injection of triamcinolone acetonide (TA) or prednisolone (PSL). Forty-two rats were divided into 3 groups: A normal saline injection group (control group), a TA injection group, and a PSL injection group; the normal saline or corticosteroid was injected around the Achilles tendon. One or 3 weeks after injection, the tendons were subjected to biomechanical testing and histological analysis. At 1 week, the biomechanical strength was significantly lower in the corticosteroid groups. Histological analysis, at 1-week post-injection, showed collagen attenuation, increased expression of MMP-3 and apoptotic cells in the corticosteroid groups. The histological changes and biomechanical weaknesses of the tendon were not seen at 3 weeks. These alterations appeared to be involved in tendon degeneration or rupture after corticosteroid injection.

Для цитирования: Muto Tomoyuki, Kokubu Takeshi, Mifune Yutaka, Inui Atsuyuki, Harada Yoshifumi, Yoshifumi, Takase Fumiaki, Kuroda Ryosuke, Kurosaka Masahiro. Temporary inductions of matrix metalloprotease-3 (MMP-3) expression and cell apoptosis are associated with tendon degeneration or rupture after corticosteroid injection.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2014. DOI: 10.1002/jor.22681.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.