m+Medelevator.RU
← Поиск публикаций
European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025

Safety and complications of antimicrobial coated compared to conventional intramedullary femoral nails in proximal femoral fractures.

СтатьяНаблюдательное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wiechert Jacob, Osterhoff Georg, Kleber Christian, Höch Andreas, Notov Dmitry

Аннотация

PURPOSE: The aim of this study was to compare one-year mortality and the incidence of complications, particularly fracture-related infections, between patients with proximal femur fractures treated with novel noble metal-coated implants and those treated with uncoated implants, to detect possible effects of the coating on these endpoints.

METHODS: Design: Retrospective cohort observational study.

SETTING: Level 1 trauma centre. Patient Selection Criteria: All patients ≥ 18 years old with proximal femur fracture, who were treated with an intramedullary femur nail between 01.09.2020 and 01.10.2022 were included. The coated group (COATED) included patients who were treated with a coated implant. The control group (CONTROL) was treated with uncoated implants. Pathological fractures were excluded.

RESULTS: 188 patients who matched the criteria were included (COATED: 93, CONTROL: 95). There was no significant difference in the one-year mortality or complication rate between the two groups. The fracture-related infection rate did not differ (p = 0.31) between both groups. Complications were observed in 59% of all cases and the overall one-year mortality rate was 42%. There was a significant correlation between complication occurrence and hospital stay (p < 0.01).

CONCLUSION: The coated intramedullary nail was similar to the uncoated nail in terms of perioperative complications and 1-year mortality rate. This suggests that the novel coated implant is safe for common clinical use. Further prospective multicentre studies with larger sample sizes are needed to detect a potential impact of coated implants on the incidence of fracture-related infections.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты