MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.1c04440

Медицинская библиотека · Analytical chemistry · 2022

Integrated Lateral Flow Electrochemical Strip for Leptospirosis Diagnosis.

Deenin Wanwisa, Yakoh Abdulhadee, Kreangkaiwal Chahya, Chailapakul Orawon, Patarakul Kanitha, Chaiyo Sudkate

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

LipL32 is an outer membrane protein present only on pathogenic Leptospira species, which is the causative agent of leptospirosis. Leptospirosis symptoms are often misdiagnosed with other febrile illnesses as the clinical manifestations are non-specific. Therefore, an accurate diagnostic tool for leptospirosis is indeed critical for proper and prompt treatment. Typical diagnosis via serological assays is generally performed to assess the antibodies produced against Leptospira. However, their delayed antibody response and complicated procedure undoubtedly limit the practical utilization especially in a primary care setting. Here, we demonstrate for the first time an early-stage detection of LipL32 by an integrated lateral-flow immunoassay with an electrochemical readout (eLFIA). A ferrocene trace tag was monitored via differential pulse voltammetry operated on a smartphone-based device, thus allowing for on-field testing. A superior performance in terms of the lowest detectable limit of detection of 8.53 pg/mL and broad linear dynamic range (5 orders of magnitude) among other sensors available thus far was established. Additionally, the developed test strip provided a straightforward yet sensitive approach for diagnosis of leptospirosis using the collected human sera from patients, in which the results were comparable to the real-time polymerase chain reaction technique.

Для цитирования: Deenin Wanwisa, Yakoh Abdulhadee, Kreangkaiwal Chahya, Chailapakul Orawon, Patarakul Kanitha, Chaiyo Sudkate. Integrated Lateral Flow Electrochemical Strip for Leptospirosis Diagnosis.. Analytical chemistry. 2022. DOI: 10.1021/acs.analchem.1c04440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.