MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11517-026-03601-4

Медицинская библиотека · Medical & biological engineering & computing · 2026

Elevated-rim liner positioning in total hip arthroplasty: a compromise between dislocation biomechanics and range of motion.

Feng Tao, Zhang Chengshuai, He Dongyang, Tang Hao, Zhang Xiaogang, Zhang Yali, Zhou Yixin, Jin Zhongmin

СтатьяПеревод в очереди

Аннотация

Dislocation remains a common complication after total hip arthroplasty (THA). Elevated-rim liners may enhance stability, but their effectiveness depends on rim orientation and cup position. This study aimed to develop a capsule-informed framework integrating dislocation biomechanics and impingement-free range of motion (IFROM) to optimize elevated-rim liner positioning. A fiber-reinforced finite element (FE) model of the hip capsule was developed and calibrated using cadaveric data. A THA model was used to quantify IFROM across combinations of liner orientation and cup position, defining impingement-free safe zones (IFSZs). Liner edge contact pressure, plastic strain, and resistive moments were evaluated under three representative dislocation maneuvers. The framework accurately reproduced capsular mechanical behavior and identified IFSZs. Hyperextension produced the most severe edge loading. Posteroinferior rim orientation reduced edge loading and increased resistive moments, particularly for posterior dislocation. A clear trade-off existed between maximizing resistive moment and preserving IFROM. Liner positioning cannot rely solely on geometric parameters. A multi-objective strategy balancing IFROM and resistive moments while maintaining safe edge loading is required. The proposed framework provides a quantitative tool for patient-specific planning to reduce mechanical failure and improve joint stability after THA.

Для цитирования: Feng Tao, Zhang Chengshuai, He Dongyang, Tang Hao, Zhang Xiaogang, Zhang Yali, Zhou Yixin, Jin Zhongmin. Elevated-rim liner positioning in total hip arthroplasty: a compromise between dislocation biomechanics and range of motion.. Medical & biological engineering & computing. 2026. DOI: 10.1007/s11517-026-03601-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.