MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12917-024-04365-5

Медицинская библиотека · BMC veterinary research · 2024

The reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in the thoracolumbar and lumbar spine of a canine large breed cadaveric model.

Mullins Ronan A, Ortega Cristina, Bleedorn Jason, Maurin Marie Pauline, Hoey Seamus, Espinel Ruperez Jorge, Kraus Karl H, Hetzel Scott J, Guevar Julien

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Spinal stabilization in dogs is challenging, and improper implant placement can result in significant morbidity. Objectives were to evaluate reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in a canine large breed cadaveric model. CT scans obtained from T6 to sacrum. Fifty-six pedicles (T7-L7) were randomized to have 1 of 5 modified Zdichavsky drill tracts (non-breached, partial/full medial breach, partial/full lateral breach). All tracts were created using 3D-printed guides. Each pedicle was probed separately by 2 investigators in randomized fashion on 2 occasions, 2 weeks apart. Post-probing CT grading of tracts was performed by one investigator, blinded to probing results. Specificity, sensitivity, positive (PPV) and negative (NPV) predictive values and times to assign grade were compared between surgeons.

RESULTS

CT identified 43 non-breached tracts, 7 medial and 5 lateral breaches. One tract was excluded because of guide misplacement. Specificity was 90.1%. PPV for detection of medial and lateral breaches was 80.0% and 57.1%. Sensitivity for medial (grade 2a/2b) and lateral (grade 3a/3b) breaches was 100.0% and 80.0%. NPV was 98.8%. Overall median time to assign grade with probe was 37.5-59.5 s. Both surgeons had very good intraobserver agreement (k,0.823 and 0.812). Interobserver agreement for round 1 was good (k,0.674) and good-to-very good for round 2 (k,0.800).

CONCLUSIONS

Use of a ball-tipped probe is associated with excellent specificity, excellent sensitivity to detect medial breaches, and good sensitivity to detect lateral breaches. This technique may be useful to confirm integrity of pedicle screw/pin tracts in dogs.

Для цитирования: Mullins Ronan A, Ortega Cristina, Bleedorn Jason, Maurin Marie Pauline, Hoey Seamus, Espinel Ruperez Jorge, Kraus Karl H, Hetzel Scott J, Guevar Julien. The reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in the thoracolumbar and lumbar spine of a canine large breed cadaveric model.. BMC veterinary research. 2024. DOI: 10.1186/s12917-024-04365-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.