MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-026-54905-2

Медицинская библиотека · Scientific reports · 2026

Effect of different washing and post-curing protocols on the fracture resistance of 3D-printed pediatric crowns after thermal cycling.

Alper Emre Serhan, Simsek Huseyin, Buyuk Suleyman Kutalmış, Guler Cigdem, Çadırcı Mustafa

СтатьяПеревод в очереди

Аннотация

Three-dimensional (3D) printing is increasingly used for pediatric crown restorations; however, post-processing procedures may critically influence their mechanical performance. This in vitro study evaluated the effects of washing and post-curing durations on the fracture resistance and fracture pattern distribution of 3D-printed pediatric crowns after thermal cycling. Ninety crowns fabricated using a digital light processing (DLP) printer were assigned to nine groups according to washing (0, 3, and 10 min of ultrasonic cleaning) and post-curing (0, 10, and 20 min) durations. After cementation onto standardized dies and 10,000 thermal cycles, fracture resistance was tested and fracture patterns were classified. Two-way analysis of variance revealed significant effects of washing and post-curing (p < 0.001), with post-curing demonstrating the strongest individual influence and a significant interaction between factors. The highest fracture resistance was observed with 10 min of ultrasonic washing followed by 10 min of post-curing, whereas prolonged post-curing reduced strength. Fracture patterns also differed significantly among groups. These findings indicate that mechanical performance depends on the coordinated interaction of post-processing steps. For the tested resin system, 10 min of ultrasonic washing followed by 10 min of post-curing appears to represent a clinically applicable protocol to maximize fracture resistance.

Для цитирования: Alper Emre Serhan, Simsek Huseyin, Buyuk Suleyman Kutalmış, Guler Cigdem, Çadırcı Mustafa. Effect of different washing and post-curing protocols on the fracture resistance of 3D-printed pediatric crowns after thermal cycling.. Scientific reports. 2026. DOI: 10.1038/s41598-026-54905-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.