Vertebral fracture after removing pedicle screws used for posterior lumbar interbody fusion: A case report.

Mataki Kentaro, Fukushima Makoto, Kaneoka Koji, Ikeda Kotaro, Kumagai Hiroshi, Nagashima Katsuya, Miura Kousei, Noguchi Hiroshi, Funayama Toru, Abe Tetsuya, Koda Masao, Yamazaki Masashi

Клинический случайСтатьяПеревод в очереди

Аннотация

It is uncommon to remove pedicle screws after posterolateral lumbar interbody fusion (PLIF), and there are a few case reports of vertebral fracture involving holes remaining after screw removal. We report a case of the vertebral fracture after removing pedicle screws instrumented for PLIF. A 66-year-old woman with osteopenia, who underwent PLIF at L4-S1 10 years earlier, underwent PLIF at L3-L4 to correct adjacent-segment degeneration. We removed L5 and S1 pedicle screws, and inserted L3 pedicle screws. After surgery, she presented with severe progressive low back pain. Computed tomography (CT) and magnetic resonance imaging (MRI) revealed an L5 body fracture involving the pedicle screw holes. Revision surgery, including posterolateral fusion from L3 to S2 alar iliac and L5 vertebroplasty, was performed. One year after the revision surgery, the patient remained pain-free and returned to normal activity. Possible reasons for instrumented vertebral body fracture after pedicle screw removal are decrease of vertebral mass, increased mechanical stress caused by PLIF at the adjacent segment, stress-shielding-related osteopenia, and spinal imbalance. Vertebral body fractures associated with spinal implant removal are rare, but possible, especially in elderly patients with osteopenia and osteoporosis.

Для цитирования: Mataki Kentaro, Fukushima Makoto, Kaneoka Koji, Ikeda Kotaro, Kumagai Hiroshi, Nagashima Katsuya, Miura Kousei, Noguchi Hiroshi, Funayama Toru, Abe Tetsuya, Koda Masao, Yamazaki Masashi. Vertebral fracture after removing pedicle screws used for posterior lumbar interbody fusion: A case report.. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia. 2018. DOI: 10.1016/j.jocn.2018.04.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.