Serum Presepsin Might Not Detect Periprosthetic Joint Infection After Hip Arthroplasty.

Hashimoto Kohei, Morishima Takkan, Watanabe Kazutaka, Ikemoto Tatsunori, Nakamura Yukio, Takahashi Nobunori

СтатьяПеревод в очереди

Аннотация

Background

The purpose of this study was to determine the normative perioperative plasmatic levels of presepsin in patients undergoing primary total hip arthroplasty (THA), and to evaluate whether presepsin measurements can effectively distinguish the presence of periprosthetic joint infection (PJI) following THA.

Methods

In study 1, we evaluated multiple inflammatory markers before and at several time points after surgery in 31 primary THA patients. The Kruskal-Wallis test was used to compare sequential changes in each variable followed by the Sheffe post hoc comparison. In study 2, we evaluated the diagnostic accuracy of the inflammatory markers for PJI using five cases with confirmed PJI without bacteremia. ROC curve analysis was performed comparing these PJI cases with the 31 preoperative cases from study 1.

Results

In study 1, presepsin levels were not significantly different from the baseline throughout the monitoring period. In study 2, the AUCs of CRP (1.0, p < 0.001) and ESR-1h (0.83, p < 0.05) in the ROC curve were able to discriminate PJI, but those of presepsin (0.51, p = 0.96) and WBC (0.65, p = 0.28) failed to discriminate PJI.

Conclusions

Our findings suggest that presepsin levels remain stable following THA and may have limited utility in detecting periprosthetic joint infection, particularly in the absence of systemic infection.

Для цитирования: Hashimoto Kohei, Morishima Takkan, Watanabe Kazutaka, Ikemoto Tatsunori, Nakamura Yukio, Takahashi Nobunori. Serum Presepsin Might Not Detect Periprosthetic Joint Infection After Hip Arthroplasty.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14124246.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.