MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1373/clinchem.2003.023994

Медицинская библиотека · Clinical chemistry · 2003

Parallel detection of autoantibodies with microarrays in rheumatoid diseases.

Feng Yanfei, Ke Xue, Ma Rongshui, Chen Ying, Hu Gengxi, Liu Feizhou

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Clinical needs often dictate testing for several autoantibodies in a single patient with evidence of autoimmune disease. We developed a microarray containing 15 autoantigens for the detection of autoantibodies in rheumatoid autoimmune diseases.

METHODS

We synthesized recombinant centromere protein B, cytokeratin 19, SSA 52-kDa antigen, SSA 60-kDa antigen, SSB antigen, and Jo-1 antigen and prepared anti-nuclear antibody antigens. Cyclic citrullinated peptide, histone, goat IgG for detection of rheumatoid factor, double-stranded DNA, and single-stranded DNA were purchased, as were recombinant small nuclear ribonucleoprotein U1, topoisomerase I, and Smith antigen (Sm). All 15 antigens were of human origin except calf thymus Sm. Proteins were printed on polystyrene. The arrays were incubated with serum samples and then with horseradish peroxidase-conjugated secondary antibodies and chemiluminescent substrates, and light signals were captured by a charge-coupled device camera-based chip reader. Antibodies were quantified by use of calibration curves. Positive samples were confirmed by commercially available methods.

RESULTS

The detection limit of the microarray system was 20 pg of IgG printed on the polystyrene support. More than 85% of the confirmed positive sera were detected as positive with the microarray system based on cutoff values established with the microarray system. The imprecision (CV) of the microarrays was <15% for all 15 autoantibody assays, with the exception of single-stranded DNA (18% and 23%) within and between batches. Characteristic autoantibody patterns were seen in patients with clinical diagnoses of rheumatoid arthritis (n = 83), systemic lupus erythematosus (n = 71), systemic sclerosis (n = 36), polymyositis (n = 38), and Sjogren syndrome (n = 20).

CONCLUSIONS

This microarray system provides results similar to those by conventional methods. Assessment of the diagnostic accuracy of the system remains to be done.

Для цитирования: Feng Yanfei, Ke Xue, Ma Rongshui, Chen Ying, Hu Gengxi, Liu Feizhou. Parallel detection of autoantibodies with microarrays in rheumatoid diseases.. Clinical chemistry. 2003. DOI: 10.1373/clinchem.2003.023994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.