MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-024-06328-9

Медицинская библиотека · International orthopaedics · 2024

Three dimensional-printed artificial disc replacement for single-level cervical spondylosis: a cohort study.

Zhang Xiao-Bo, Gao Zilin, Yao Xin, Xu Zheng-Wei, Hao Ding-Jun

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare the clinical efficacy of 3D-printed artificial discs with that of ACDF for treating cervical spondylosis.

METHODS

This was a retrospective analysis of 73 patients with single-level cervical spondylosis who met the inclusion criteria between January 2020 and December 2022 at XX Hospital. The patients were divided: 38 patients in the ACDF group and 35 patients in the CADR group. Patient general information, including operation time and intraoperative blood loss, was collected. The clinical effect of the combination therapy was evaluated by the VAS, JOA, and NDI. The radiological effect was evaluated using the ROM test. Ethics No. 201,606,009.

RESULTS

The average follow-up times in the ACDF and CADR groups were 28.24 ± 4.65 and 29.11 ± 5.06 months, respectively (P = 0.443). Clinical symptoms (evaluated by VAS, NDI, and JOA) are significantly improved in both the ACDF and CADR groups with similar efficacy. The preoperative ROM of the ACDF group was 40.03 ± 8.79, while that of the CADR group was 42.11 ± 7.98 (P = 0.293). However, the postoperative ROM in the ACDF group was 35.29 ± 7.23, which was lower than that in the CADR group (40.43 ± 6.98) (P = 0.003). Furthermore, only one patient in the ACDF group experienced mild dysphagia after surgery, and the patient recovered within three days. ASD occurred in nine patients in the ACDF group and in two patients in the CADR group (Χ²=4.597, P = 0.032).

CONCLUSIONS

Compared with ACDF, 3D-printed artificial discs for treating single-level cervical spondylosis have proven to be clinically effective; it associated with less blood loss and a lower incidence of ASD, and maintain a better cervical ROM.

Для цитирования: Zhang Xiao-Bo, Gao Zilin, Yao Xin, Xu Zheng-Wei, Hao Ding-Jun. Three dimensional-printed artificial disc replacement for single-level cervical spondylosis: a cohort study.. International orthopaedics. 2024. DOI: 10.1007/s00264-024-06328-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.