DOI 10.1016/j.arthro.2024.02.032

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2024

The Arthroscopic Subscapular Sling Procedure Results in Low Recurrent Anterior Shoulder Instability at 24 Months of Follow-Up.

Klungsøyr Jan Arild, Vagstad Terje, Klungsøyr Peter Johannes, Myklebust Tor Åge, Lund Hanssen Håkon, Hoff Solveig Roth, Drogset Jon Olav

СтатьяПеревод в очереди

Аннотация

PURPOSE: To analyze the results of the subscapular sling procedure developed for anterior shoulder instability in patients with less than 10% anterior glenoid bone loss.

METHODS

Patients were treated surgically with the arthroscopic subscapular sling procedure. A semitendinosus graft was used to reconstruct the anterior labrum and to establish a sling suspension around the upper part of the subscapularis tendon. The patients were followed up with radiographs (at 12 and 24 months). Magnetic resonance imaging (MRI) of the shoulder region and clinical examinations were performed at 3, 12, and 24 months. Recurrent dislocation was the primary endpoint. The Western Ontario Shoulder Instability Index (WOSI) and MRI results were secondary outcome measures. An independent physiotherapist assessed residual instability and range of motion.

RESULTS

Fifteen patients were included with a dislocation rate of 0% after 24 months follow-up. There was a significant clinical improvement of the WOSI score from 57% (904) at baseline to 88% (241) at 24 months (P < .001). The proportion of patients with an improvement in the WOSI Total score larger than the estimated minimal clinically important difference was 100% both at 12 and 24 months. MRI showed an intact sling in all patients. External rotation was not significantly reduced (52° at baseline vs 47° at 24 months, P = .211). Flexion and abduction were significantly improved from 152° to 174° (P = .001) and 141° to 170° (P < .001) after 24 months. The surgical procedures were completed without any intraoperative complications.

CONCLUSIONS

The subscapular sling procedure resulted in low recurrent shoulder instability and improved patient-reported outcome measures at 24 months of follow-up.

LEVEL OF EVIDENCE: Level IV, case series.

Для цитирования: Klungsøyr Jan Arild, Vagstad Terje, Klungsøyr Peter Johannes, Myklebust Tor Åge, Lund Hanssen Håkon, Hoff Solveig Roth, Drogset Jon Olav. The Arthroscopic Subscapular Sling Procedure Results in Low Recurrent Anterior Shoulder Instability at 24 Months of Follow-Up.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2024. DOI: 10.1016/j.arthro.2024.02.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.