MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0318004

Медицинская библиотека · PloS one · 2025

Low-profile double plating versus conventional single plating in midshaft clavicle fractures: A retrospective study and initial experience with this novel technique.

Lecoultre Yannic, van de Wall Bryan, Link Bjoern-Christian, Kik Charlotte, Babst Reto, Beeres Frank

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.

METHODS

This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center. Exclusion criteria encompassed pathological or open fractures, refractures and delayed presentation or treatment more than 14 days after the accident. Patients were categorized into two treatment groups: Single plating (Synthes 3.5mm LCP superior / anterior or Synthes 2.7mm VA-LCP superior) and low-profile double plating (2.0 superior combined with either 2.4 or 2.7mm anterior mini-plate). Treatment groups were compared regarding healing, complications, and removal rate.

RESULTS

A total of 99 patients were included: 74 in the single plating and 25 in the double plating group. Implant failures within the first three months were comparable in both groups (4.0% double plating versus 2.7% single, p = 0.744, of which one was caused by infection). Low-profile double plating had a significantly lower operation duration (95 versus 111 minutes, p = 0.019). Long-term follow-up data was available in 60 patients in the single plating and 20 in the double plating group. The need for reintervention was significantly lower in the double plating group (n = 5, 25.0% vs. n = 31, 51.7%, p = 0.038). These reinterventions were predominantly caused by implant irritation in both groups (n = 4, 20% double plating versus n = 29, 48.3% single plating, p = 0.026). All fractures healed in both groups.

CONCLUSION

Low-profile double plating attains comparable healing rates as single plating and has a significantly lower risk for re-intervention as well as a shorter operation duration. The lower reintervention rate is mainly explained by a lower incidence of implant irritation in the double plating group.

Для цитирования: Lecoultre Yannic, van de Wall Bryan, Link Bjoern-Christian, Kik Charlotte, Babst Reto, Beeres Frank. Low-profile double plating versus conventional single plating in midshaft clavicle fractures: A retrospective study and initial experience with this novel technique.. PloS one. 2025. DOI: 10.1371/journal.pone.0318004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.