MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-016-2612-8

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2017

The accuracy of a hand-held navigation system in total knee arthroplasty.

Loh Bryan, Chen Jerry Yongqiang, Yew Andy Khye Soon, Pang Hee Nee, Tay Darren Keng Jin, Chia Shi-Lu, Lo Ngai Nung, Yeo Seng Jin

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery.

PATIENTS AND

METHODS

Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180° ± 3° for the HKA and 90° ± 3° for both the CFA and CTA.

RESULTS

For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 ± 9 min and 87 ± 15 min in the hand-held navigation and conventional group, respectively (p < 0.001).

CONCLUSION

This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively.

LEVEL OF EVIDENCE: III.

Для цитирования: Loh Bryan, Chen Jerry Yongqiang, Yew Andy Khye Soon, Pang Hee Nee, Tay Darren Keng Jin, Chia Shi-Lu, Lo Ngai Nung, Yeo Seng Jin. The accuracy of a hand-held navigation system in total knee arthroplasty.. Archives of orthopaedic and trauma surgery. 2017. DOI: 10.1007/s00402-016-2612-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.