Background

The gate control theory asserts that non-painful stimuli can block pain perception. The ShotBlocker™ device is a plastic disk with blunt projections that rests on the skin, and we hypothesize that it will reduce pain during hand injections.

Methods

This is a prospective randomized trial of 117 patients undergoing injections for common hand conditions. Patients were randomized into 3 groups: device, placebo (device with projections removed), and control. Patients recorded on an analog pain scale the pain severity of the injection, as well as their most recent tetanus shot. A normalized pain score was obtained from the difference between the injection and tetanus shot pain scores. The mean non-normalized and normalized scores for each treatment group were compared to the control group using the Wilcoxon signed rank test.

Results

There were 91 women and 26 men. Common diagnoses included trigger finger (n = 53), DeQuervain's tendonitis (n = 33), and basal joint arthritis (n = 22). The groups did not differ significantly in age, gender, or diagnosis. Mean pain score in the device group was 5.2 out of 10, and it was 5.7 for the control group. The normalized pain score in the device group was significantly lower than the control group. Normalized and non-normalized pain scores for the placebo group were not significantly lower than the control group.

Conclusions

The shot blocking device effectively reduced pain of injection versus controls when pain scores were normalized for pain tolerance. The modified device did not reduce the pain of injection, suggesting that gate control is the mechanism of action.

Для цитирования: Rinker Brian D, Atashroo David A, Stout Megan A, Wermeling F Ryan. The Effectiveness of a Non-Invasive Shot Blocking Device for Reducing Pain of In-office Injections in Hand Surgery.. Hand (New York, N.Y.). 2019. DOI: 10.1177/1558944719884655.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.