MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000002578

Медицинская библиотека · Journal of orthopaedic trauma · 2023

Comparative Analysis of Supplemental Medial Buttress Plate Fixation for High-Energy Displaced Femoral Neck Fractures in Young Adults.

Collinge Cory A, Harris Payton, Sagi H Claude, Rodriguez-Buitrago Andres, Beltran Michael J, Mitchell Phillip M, Mir Hassan R, Lebus George F, Tornetta Paul, de la Fuente Guadalupe, Young Femoral Neck Fracture Working Group

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate whether augmenting traditional fixation with a femoral neck buttress plate (FNBP) improves clinical outcomes in young adults with high-energy displaced femoral neck fractures.

DESIGN

Multicenter retrospective matched cohort comparative clinical study.

SETTING

Twenty-seven North American Level 1 trauma centers.

PATIENTS: Adult patients younger than 55 years who sustained a high-energy (nonpathologic) displaced femoral neck fracture.

INTERVENTION: Operative reduction and stabilization of a displaced femoral neck fracture with (group 1) and without (group 2) an FNBP.

MAIN OUTCOME MEASUREMENTS: Complications including failed fixation, nonunion, osteonecrosis, malunion, and need for subsequent major reconstructive surgery (early revision of reduction and/or fixation), proximal femoral osteotomy, or arthroplasty.

RESULTS

Of 478 patients younger than 55 years treated operatively for a displaced femoral neck fracture, 11% (n = 51) had the definitive fixation augmented with an FNBP. One or more forms of treatment failure occurred in 29% (n = 15/51) for group 1 and 49% (209/427) for group 2 ( P < 0.01). When FNBP fixation was used, mini-fragment (2.4/2.7 mm) fixation failed significantly more often than small-fragment (3.5 mm) fixation (42% vs. 5%, P < 0.01). Irrespective of plate size, anterior and anteromedial plates failed significantly more often than direct medial plates (75% and 33% vs. 9%, P < 0.001).

CONCLUSIONS

The use of a femoral neck buttress plate to augment traditional fixation in displaced femoral neck fractures is associated with improved clinical outcomes, including lower rates of failed fixation, nonunion, osteonecrosis, and need for secondary reconstructive surgery. The benefits of this technique are optimized when a small-fragment (3.5 mm) plate is applied directly to the medial aspect of the femoral neck, avoiding more anterior positioning .

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Collinge Cory A, Harris Payton, Sagi H Claude, Rodriguez-Buitrago Andres, Beltran Michael J, Mitchell Phillip M, Mir Hassan R, Lebus George F, Tornetta Paul, de la Fuente Guadalupe, Young Femoral Neck Fracture Working Group. Comparative Analysis of Supplemental Medial Buttress Plate Fixation for High-Energy Displaced Femoral Neck Fractures in Young Adults.. Journal of orthopaedic trauma. 2023. DOI: 10.1097/bot.0000000000002578.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.