BACKGROUND

Froin syndrome is characterized by xanthochromia and hypercoagulability of the cerebrospinal fluid (CSF) due to elevated protein levels. This entity results from blockage of the spinal canal by a mass lesion leading to an isolated caudal CSF space.

CASE DESCRIPTION: A 48-year-old male, who developed spasticity after a C6 spinal cord injury (SCI) 20 years earlier, presented with subobstruction of his intrathecal baclofen pump. A catheter access port aspiration revealed an extremely high protein concentration (38 g/L) with no signs of infection. Froin syndrome was confirmed when magnetic resonance imaging showed a complete obstruction of the spinal canal at the SCI level.

CONCLUSIONS

We report the first case of Froin syndrome after SCI. Froin syndrome can impact intrathecal drug delivery and CSF diagnostics.

Для цитирования: Decramer Thomas, Wouters Anke, Kiekens Carlotte, Theys Tom. Froin Syndrome After Spinal Cord Injury.. World neurosurgery. 2019. DOI: 10.1016/j.wneu.2019.04.198.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.