MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04753-2

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2023

Avascular necrosis of the femoral head: three-dimensional measurement of drilling precision reveals high accuracy and no difference between fluoroscopically controlled core decompression and cancellous bone grafting.

Woerner Michael, Voelkl Korbinian, Ferner Felix, Weber Markus, Renkawitz Tobias, Grifka Joachim, Craiovan Benjamin

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Avascular osteonecrosis of the femoral head (AVN) is a widespread disease affecting mostly young and active people, often exacerbating in progressive stages, ending in joint replacement. The most common joint preserving operative therapy for early stages is core decompression (CD), optional with cancellous bone grafting (CBG). For success it is vital that the necrotic area is hit and the sclerotic rim is broken by drilling into the defect zone to relieve intraosseous pressure. The aim of this study was to investigate if both techniques are precise enough to hit the center of the necrosis and if there is a difference in precision between drilling with small pins (CD) and the trephine (CBG).

PATIENTS AND

METHODS

10 patients underwent CD, 12 patients CBG with conventional C-arm imaging. Postoperatively 3D MRI reconstructions of the necrotic area and the drilling channels were compared. The deviation of the drilling channel from the center of the necrotic area was measured. PROMs (HHS, HOOS, EQ-5D, SF-36) were evaluated to compare the clinical success of these procedures.

RESULTS

Neither with CD nor with CBG the defect zone was missed. The drilling precision of both procedures did not differ significantly: distance to center 3.58 mm for CD (range 0.0-14.06, SD 4.2) versus 3.91 mm for CBG (range 0.0-15.27, SD 4.7). PROMs showed no significant difference.

CONCLUSION

Concerning the most important difference between the two procedures-the surgical higher demanding technique of CBG-we suggest applying the less invasive technique of CD alone.

Для цитирования: Woerner Michael, Voelkl Korbinian, Ferner Felix, Weber Markus, Renkawitz Tobias, Grifka Joachim, Craiovan Benjamin. Avascular necrosis of the femoral head: three-dimensional measurement of drilling precision reveals high accuracy and no difference between fluoroscopically controlled core decompression and cancellous bone grafting.. Archives of orthopaedic and trauma surgery. 2023. DOI: 10.1007/s00402-022-04753-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.