MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wnsx.2024.100390

Медицинская библиотека · World neurosurgery: X · 2024

Robotic endoscopic transforaminal lumbar interbody fusion: A single institution case series.

Saway B F, Cunningham C, Pereira M, Sowlat M, Elawady S S, Porto G, Barley J, Nordmann Nathan, Frankel B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Robotic-assisted, endoscopic transforaminal lumbar interbody fusion (RE-TLIF) is a promising, minimally invasive surgical option for degenerative lumbar spondylosis/spondylolisthesis; however, outcomes data and efficacy are limited, especially in multilevel disease. Here, we present the first reported series of patients that underwent either single or multilevel RE-TLIF.

METHODS

A retrospective review was performed on 23 consecutive patients who underwent a single level or multilevel RE-TLIF by a single surgeon. Variables included demographics, perioperative results, pain scores, and functional outcome scores.

RESULTS

Eighteen patients (78.3 %) underwent single level RE-TLIF and 5 patients (21.7 %) underwent multilevel RE-TLIF. The median reduction of visual analog scale (VAS) for low back pain (LBP) of all subjects was 6 (IQR = 4.5, 6.5) with no significant difference between single level and multilevel RE-TLIF (p = 0.565). The median reduction of VAS for leg pain of all subjects 7 (IQR = 6, 8) with no significant difference between single level and multilevel RE-TLIF (p = 0.702). Median blood loss was 25 cc (IQR = 25, 25) and 50 cc (IQR = 25, 100) for single and multilevel RE-TLIF, respectively (p = 0.025), whereas median length of stay was 1 (IQR = 1, 1; mean = 1.0 ± 00.18) days and 1 (IQR = 1, 2; mean = 1.4 ± 00.54) days, respectively (p = 0.042). One major complication was observed requiring reoperation for demineralized bone matrix migration resulting in an L5 radiculopathy.

CONCLUSIONS

Single and multi-level RE-TLIF appears to be a safe and efficacious approach with comparable outcomes to open and other minimally invasive approaches. Additionally, we observed favorable accuracy in robot-assisted pedicle screw, endoscope, and interbody device placement.

Для цитирования: Saway B F, Cunningham C, Pereira M, Sowlat M, Elawady S S, Porto G, Barley J, Nordmann Nathan, Frankel B. Robotic endoscopic transforaminal lumbar interbody fusion: A single institution case series.. World neurosurgery: X. 2024. DOI: 10.1016/j.wnsx.2024.100390.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.