MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-25581-9

Медицинская библиотека · Scientific reports · 2022

Effect of thermal osteonecrosis around implants in the rat tibia: numerical and histomorphometric results in context of implant removal.

Kniha Kristian, Hermanns-Sachweh Benita, Al-Sibai Faruk, Kneer Reinhold, Möhlhenrich Stephan Christian, Heitzer Marius, Hölzle Frank, Modabber Ali

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The purpose of this rat study was to explore the feasibility of in vivo temperature thresholds affecting bone contact at the implant surface. Based on these data, thermal necrosis should be used for implant removal in the subsequent in vivo study. Rat tibiae of 48 animals at one site were randomly treated with heat or cold before implant insertion. Temperatures of 4 °C, 3 °C, 2 °C, 48 °C, 49 °C and 50 °C for a tempering time of 1 min were evaluated. Numerical simulations of the heat source-implant-bone system were carried out. Effects were assessed by histomorphometrical measurements. The results showed that the selected method of direct tempering using a tempering pin was suitable for maintaining a uniform layer around the pin. Starting at warm temperatures of 48 °C and rising to 50 °C, the BIC ratio revealed declining values and a significant difference was observed when comparing 50 °C to the control group (p = 0.03). However, there were no significant variations within the cold temperatures. This study pinpointed temperature discovered that could lead to the thermo-explantation and so that the number of samples used in future studies on temperature-induced bone necrosis can be reduced to a minimum. Significant BIC value reduction was seen at a temperature of 50 °C for 1 min.

Для цитирования: Kniha Kristian, Hermanns-Sachweh Benita, Al-Sibai Faruk, Kneer Reinhold, Möhlhenrich Stephan Christian, Heitzer Marius, Hölzle Frank, Modabber Ali. Effect of thermal osteonecrosis around implants in the rat tibia: numerical and histomorphometric results in context of implant removal.. Scientific reports. 2022. DOI: 10.1038/s41598-022-25581-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.