MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000005147

Медицинская библиотека · Spine · 2024

Pedicle Screw Placement With Augmented Reality Versus Robotic-Assisted Surgery.

Altorfer Franziska C S, Kelly Michael J, Avrumova Fedan, Burkhard Marco D, Zhu Jiaqi, Abel Frederik, Cammisa Frank P, Sama Andrew, Farshad Mazda, Lebl Darren R

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

STUDY

DESIGN

This was a single-center prospective clinical and radiographic analysis of pedicle screw instrumentation with robotic-assisted navigation (RAN) and augmented reality (AR).

OBJECTIVE

This study aimed to compare the accuracy of lumbosacral pedicle screw placement with RAN versus AR.

SUMMARY OF BACKGROUND DATA: RAN and AR have demonstrated superior accuracy in lumbar pedicle screw placement compared with conventional free-hand techniques. RAN and AR techniques both tout-specific advantages over their counterparts, but to date, no study has directly compared the two technologies regarding pedicle screw accuracy.

PATIENTS AND

METHODS

Patients who underwent RAN or head-mounted AR navigated lumbosacral (L1-S1) pedicle screw placement for degenerative conditions were included. Screw accuracy was assessed by two independent reviewers on intraoperative 3D fluoroscopic scans using the Gertzbein and Robbins scale. A generalized linear mixed model was applied to evaluate the relationship between the screw placement technique and accuracy.

RESULTS

Two hundred and twelve patients undergoing lumbosacral instrumentation with a total of 1211 pedicle screws placed using RAN (n=108; screws=827) or AR (n=104; screws=384). Overall, grade A was achieved in 92.6% of screws. No significant difference was found between RAN and AR screw placement regarding the incidence of accurate (grade A and B screws; RAN n=824; 99.6% and AR n=379, 98.7%) versus inaccurate screws (grade C and D screws; RAN n=3, 0.4% and AR n=5, 1.3%). When comparing "optimal" grade A screws (RAN n= 787, 95.2%, AR n=345, 89.8%) versus all other screws (B, C, and D), significantly higher accuracy was achieved using RAN ( P =0.001).

CONCLUSION

RAN and AR both achieved high accuracy in lumbosacral pedicle screw placement, proving reliable for this procedure. However, RAN resulted in significantly more grade A screw placements than AR.

Для цитирования: Altorfer Franziska C S, Kelly Michael J, Avrumova Fedan, Burkhard Marco D, Zhu Jiaqi, Abel Frederik, Cammisa Frank P, Sama Andrew, Farshad Mazda, Lebl Darren R. Pedicle Screw Placement With Augmented Reality Versus Robotic-Assisted Surgery.. Spine. 2024. DOI: 10.1097/brs.0000000000005147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.