MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-017-1898-1

Медицинская библиотека · BMC musculoskeletal disorders · 2017

Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.

Miura Michiaki, Nakamura Junichi, Matsuura Yusuke, Wako Yasushi, Suzuki Takane, Hagiwara Shigeo, Orita Sumihisa, Inage Kazuhide, Kawarai Yuya, Sugano Masahiko, Nawata Kento, Ohtori Seiji

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Finite element analysis (FEA) of the proximal femur has been previously validated with large mesh size, but these were insufficient to simulate the model with small implants in recent studies. This study aimed to validate the proximal femoral computed tomography (CT)-based specimen-specific FEA model with smaller mesh size using fresh frozen cadavers.

METHODS

Twenty proximal femora from 10 cadavers (mean age, 87.1 years) were examined. CT was performed on all specimens with a calibration phantom. Nonlinear FEA prediction with stance configuration was performed using Mechanical Finder (mesh,1.5 mm tetrahedral elements; shell thickness, 0.2 mm; Poisson's coefficient, 0.3), in comparison with mechanical testing. Force was applied at a fixed vertical displacement rate, and the magnitude of the applied load and displacement were continuously recorded. The fracture load and stiffness were calculated from force-displacement curve, and the correlation between mechanical testing and FEA prediction was examined.

RESULTS

A pilot study with one femur revealed that the equations proposed by Keller for vertebra were the most reproducible for calculating Young's modulus and the yield stress of elements of the proximal femur. There was a good linear correlation between fracture loads of mechanical testing and FEA prediction (R2 = 0.6187) and between the stiffness of mechanical testing and FEA prediction (R2 = 0.5499). There was a good linear correlation between fracture load and stiffness (R2 = 0.6345) in mechanical testing and an excellent correlation between these (R2 = 0.9240) in FEA prediction.

CONCLUSIONS

CT-based specimen-specific FEA model of the proximal femur with small element size was validated using fresh frozen cadavers. The equations proposed by Keller for vertebra were found to be the most reproducible for the proximal femur in elderly people.

Для цитирования: Miura Michiaki, Nakamura Junichi, Matsuura Yusuke, Wako Yasushi, Suzuki Takane, Hagiwara Shigeo, Orita Sumihisa, Inage Kazuhide, Kawarai Yuya, Sugano Masahiko, Nawata Kento, Ohtori Seiji. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.. BMC musculoskeletal disorders. 2017. DOI: 10.1186/s12891-017-1898-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.