Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated aortic bioprosthesis.

Bruschi Giuseppe, DeMarco Federico, Oreglia Jacopo, Colombo Paola, Fratto Pasquale, Lullo Francesca, Paino Roberto, Martinelli Luigi, Klugmann Silvio

Клинический случайСтатьяПеревод в очереди

Аннотация

In recent years percutaneous aortic valve implantation has emerged as an alternative therapy to treat patients with symptomatic aortic stenosis considered to be high-risk surgical candidates. We report our experience of a percutaneous retrograde CoreValve implantation in a 77-year-old female with aortic bioprosthesis structural degeneration. The patient underwent aortic valve replacement for aortic stenosis in 1999 with the implantation of a 23 mm Carpentier-Edwards; her last echocardiography showed a severe bioprosthesis stenosis. After evaluation by cardiac surgeons and cardiologist, considering the high risk re-do surgical procedure (Logistic Euroscore 30%) and severe comorbidities (severe pulmonary hypertension, hepatocellular carcinoma and severe osteoporosis), a percutaneous aortic valve-in-valve replacement was preferred. A successful percutaneous 26 mm CoreValve prosthesis implantation was performed with the patient awake with local anesthesia and mild sedation. The patient was discharged after 10 days of hospitalization and she is in NYHA functional class I at follow-up. Our experience, characterized by a multidisciplinary approach, necessary to offer the safest conditions and care for patients, demonstrates the feasibility of a new, promising indication for the use of a transcatheter valve implantation: percutaneous treatment of a degenerated aortic bioprosthesis.

Для цитирования: Bruschi Giuseppe, DeMarco Federico, Oreglia Jacopo, Colombo Paola, Fratto Pasquale, Lullo Francesca, Paino Roberto, Martinelli Luigi, Klugmann Silvio. Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated aortic bioprosthesis.. Journal of cardiovascular medicine (Hagerstown, Md.). 2010. DOI: 10.2459/jcm.0b013e32832ffcb4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.