MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2020/4720819

Медицинская библиотека · Case reports in ophthalmological medicine · 2020

An Unusual Retinal Vessel Modification in Patients Affected by JIA-Uveitis with a Follow-Up Longer Than 16 Years.

Abbouda Alessandro, Abicca Irene, Bruschi Simone, Ricci Federico, Aloe Gianluca, Paroli Maria Pia

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To report unusual and rare clinical changes of retinal vessel pattern in a series of patients affected by Juvenile Idiopathic Arthritis (JIA) uveitis with a follow-up longer than 16 years.

METHODS

A series of three patients with JIA-uveitis followed at the University of Rome "Sapienza" from 1998 to 2014 were reported. The retinal vessels were analyzed with fluorescein angiography using Heidelberg Retinal Angiogram-2 (HRA-2; Heidelberg Engineering GmBH, Dossenheim, Germany) and the Topcon TRC-50LX retinal camera (Topcon Europe, The Netherlands). A Spectralis Domain OCT (SD-OCT) (Spectralis Family Heidelberg, Germany) was performed to evaluate vessel anatomy.

RESULTS

Fundus photography showed sheathed vessels localized around the optic disc in every case. Angiography revealed a normal physiology of vessel walls and flow; no sheathing or leakage of dye was observed. SD-OCT demonstrated reflective vessel walls. Vessel lumen appeared patent, and the normal "hourglass configuration" was blurred, but identifiable.

CONCLUSIONS

Vessel modifications observed in long-standing JIA-uveitis are not signs of vascular inflammation and are not associated to hypoperfusion. In these cases, ophthalmologists should avoid further invasive investigation and should consider introducing SD-OCT as a routine method to evaluate the vessel changes during the follow-up.

Для цитирования: Abbouda Alessandro, Abicca Irene, Bruschi Simone, Ricci Federico, Aloe Gianluca, Paroli Maria Pia. An Unusual Retinal Vessel Modification in Patients Affected by JIA-Uveitis with a Follow-Up Longer Than 16 Years.. Case reports in ophthalmological medicine. 2020. DOI: 10.1155/2020/4720819.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.