MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ymgme.2025.109257

Медицинская библиотека · Molecular genetics and metabolism · 2025

Clinical utility of the ATP hydrolysis assay for the diagnosis of complex V deficiency in cultured skin fibroblasts.

Friederich Marisa W, Van Hove Johan L K

СтатьяПеревод в очереди

Аннотация

Complex V catalyzes the formation of ATP from ADP and Pi through the dissipation of the proton gradient generated during the process of oxidative phosphorylation. Most complex V genetic disorders are caused by missense mutations in the mtDNA-encoded subunits, a (MT-ATP6) and A6L (MT-ATP8). Nuclear DNA-encoded gene mutations are increasingly recognized as causes of complex V defects and exhibited both autosomal recessive and autosomal dominant inheritance. Most identified variants are novel and confirmation by functional assays is important especially for variants demonstrating autosomal dominant inheritance. A kinetic spectrophotometric assay of the Complex V enzymatic hydrolysis activity has been reported. Here we report the clinical utility of this assay for the diagnosis of complex V deficiency after optimization and validation for the diagnosis of isolated complex V disorders due to both nuclear and mitochondrial DNA encoded variants and also for use in combined respiratory chain deficiencies. This assay was able to identify all nuclear DNA-encoded complex V deficiencies, whereas a decrease in complex V activity was observed in some patient cell lines with combined deficiencies. However, this assay only identified 50% of the mitochondrial DNA-encoded complex V deficiencies due to pathogenic variants in MT-ATP6/8. In conclusion, the enzymatic assay of complex V has best clinical utility for nuclear DNA-encoded complex V defects.

Для цитирования: Friederich Marisa W, Van Hove Johan L K. Clinical utility of the ATP hydrolysis assay for the diagnosis of complex V deficiency in cultured skin fibroblasts.. Molecular genetics and metabolism. 2025. DOI: 10.1016/j.ymgme.2025.109257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.