m+Medelevator.RU
← Поиск публикаций
Annals of the rheumatic diseases · 2012

Dual energy CT in gout: a prospective validation study.

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Choi Hyon K, Burns Lindsay C, Shojania Kamran, Koenig Nicole, Reid Graham, Abufayyah Mohammed, Law Genevieve, Kydd Alison S, Ouellette Hugue, Nicolaou Savvas

Аннотация

OBJECTIVE: The authors prospectively determined: (1) the specificity and sensitivity of dual energy CT (DECT) for gout; and (2) the interobserver and intraobserver reproducibility for DECT urate volume measurements.

METHODS: Forty crystal-proven gout patients (17 tophaceous) and 40 controls with other arthritic conditions prospectively underwent DECT scans of all peripheral joints using a gout protocol that color-codes the composition of tissues. A blinded radiologist identified urate deposition to calculate specificity and sensitivity of DECT for gout. Inter-rater volumetric reproducibility was determined by two independent radiologists on 40 index tophi from the 17 tophaceous gout patients using automated software.

RESULTS: The mean age of the 40 gout patients was 62 years, the mean gout duration was 13 years and 87% had a history of urate-lowering therapy (ULT). The specificity and sensitivity of DECT for gout were 0.93 (95% CI, 0.80 to 0.98) and 0.78 (0.62 to 0.89), respectively. When the authors excluded three gout cases with unreadable or incomplete scans, the sensitivity was 0.84 (95% CI, 0.68 to 0.94). The urate volumes of 40 index tophi ranged from 0.06 cm(3) to 18.74 cm(3) with a mean of 2.45 cm(3). Interobserver and intraobserver intraclass correlation coefficients for DECT volume measurements were 1.00 (95% CI, 1.00 to 1.00) and 1.00 (95% CI, 1.00 to 1.00) with corresponding bias estimates (SD) of 0.01 (0.00) cm(3) and 0.01 (0.03) cm(3).

CONCLUSIONS: These prospective data indicate high reproducibility of DECT urate volume measures. The specificity was high, but sensitivity was more moderate, potentially due to frequent ULT use in our patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты