DOI 10.1186/s10195-026-00919-5
From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty.
Аннотация
BACKGROUND
Stable fixation of the greater trochanter during hip arthroplasty for unstable osteoporotic intertrochanteric fractures remains a significant challenge. Conventional techniques depend on securing the bone-implant interface, which is particularly compromised in osteoporotic bone. Here, we propose a novel conceptual approach that establishes a direct mechanical bridge from the abductor tendon to the prosthesis, thereby reducing reliance on the fragile bone-implant interface.
METHODS
In this two-stage translational study, we progressed from biomechanical validation to clinical application. First, using a decalcified caprine femoral model simulating osteoporosis, three fixation constructs were compared: locking plate (LP), suture-augmented locking plate (LPSA), and Kirschner-wire tension band (KWTB). Ultimate load and construct stability were evaluated. Biomechanical testing confirmed the principle of suture-mediated load sharing and highlighted the intrinsic weakness of screw fixation in osteoporotic bone. Guided by these results, we designed a novel femoral prosthesis that eliminates screw fixation, employs sutures as the primary load-bearing element, and incorporates integrated suture anchor tunnels. This prosthesis was then assessed in a retrospective series of 15 consecutive elderly patients with osteoporotic intertrochanteric fractures. Clinical outcomes were evaluated using the Harris Hip Score (HHS).
RESULTS
Biomechanically, the LPSA construct sustained a significantly higher ultimate load than the LP construct in decalcified bone (P < 0.001) and exhibited a greater load at 2-mm displacement than the KWTB construct (P < 0.001). Clinically, all patients achieved fracture union without prosthesis-related complications. The mean HHS at final follow-up was 88.27 ± 6.60, and 80% of patients regained independent ambulation.
CONCLUSIONS
A prosthesis-anchored, suture-mediated "tendon-to-prosthesis" load pathway provides reliable stabilization of the greater trochanter in osteoporotic bone. Biomechanical validation and favorable early clinical outcomes support the potential of this novel fixation strategy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.