MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.13151

Медицинская библиотека · Clinical implant dentistry and related research · 2022

Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone.

Tur Dino, Giannis Katharina, Unger Ewald, Mittlböck Martina, Rausch-Fan Xiaohui, Strbac Georg D

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Excessive surgical trauma is believed to be among the most important causes for early implant losses. As thermal injury to the bone is not only dependent on the amount of generated heat but also on the tissue exposure time, and the greatest temperature increase was found within the withdrawing period, the entire osteotomy procedure with the parameters contributing to thermal damage is of particular clinical relevance. The aim of this study was to investigate the thermal performance of metal-based and ceramic implant drills regarding the temperature exposure time during the whole osteotomy process.

MATERIALS AND

METHODS

This investigation consisted of 240 individual preparations in total, comprising two different drilling depths (10 and 16 mm), two irrigation methods (external and without irrigation), two implant drill materials (stainless steel and zirconia), and three consecutive drill diameters per material (2.0/2.2, 2.8, and 3.5 mm) with 10 identical repetitions. Real-time multichannel temperature measurement was conducted during automated drilling procedures in standardized bovine bone specimens.

RESULTS

The maximum temperature changes were highly associated with the time period of passive drill withdrawing (p ≤ 0.05), irrespective of drill material, drilling depth, or drill diameter. Statistically significant differences in temperature generation between stainless steel and ceramic drills were observed in irrigated testing sites at both drilling depths with smaller drill diameters (2.0/2.2 and 2.8 mm, p ≤ 0.05).

CONCLUSION

Results of this in vitro study could demonstrate a strong association between the highest temperature increase and the passive withdrawing time period in both investigated drill materials. Considering these findings and the resulting thermal bone damage due to the whole surgical procedure, high overall temperatures in combination with a prolonged heat exposure time may impact the future osseointegration process.

Для цитирования: Tur Dino, Giannis Katharina, Unger Ewald, Mittlböck Martina, Rausch-Fan Xiaohui, Strbac Georg D. Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone.. Clinical implant dentistry and related research. 2022. DOI: 10.1111/cid.13151.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.