Psychophysiology · 2026
Individual Differences in Heartbeat-Tone Synchronicity Judgments Suggest the Two-Alternative Heartbeat Detection Task Is a Poor Test of Cardiac Interoceptive Accuracy and Insight.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Adams Kiera Louise, Palmer Ren, Bird Jonathan M, Plans David, Cunningham Adam, Morelli Davide, Piercy Tom, Spooner Ria, Clemente Rhea, Izagirre Nerea Irigoras, Fueyo Elisa Fernandez, Watling Dawn, Brewer Rebecca, Budworth Gemma, Cocirla Dorina, Leganes-Fonteneau Mateo, Todd Jennifer, Aspell Jane E, Bird Geoffrey, Murphy Jennifer
Аннотация
Despite concerns regarding its validity, the two-alternative forced-choice heartbeat detection task (2AFC-HDT) is a frequently used measure of cardiac interoceptive accuracy. In this task, participants must decide whether a series of tones occur synchronously with their heartbeats. One series of tones is predefined by the researcher as synchronous with heartbeats, and one series is predefined as asynchronous. The 2AFC-HDT may result in individuals judged to be not interoceptive when they are, either if participants perceive their heartbeats as occurring synchronously with tones predefined as asynchronous rather than synchronous with their heartbeats, or if they do not perceive either set of tones as synchronous. Currently, there is little data on the proportion of participants this may affect. We addressed this using data from the Phase Adjustment Task (PAT) - a measure of cardiac interoceptive accuracy that determines if, and when in the cardiac cycle, a participant can perceive their heartbeat. The timing of heartbeat perception in 43 interoceptive participants was compared to the timing of synchronous and asynchronous tones used in the 2AFC-HDT, assuming temporal precision of 50, 100, and 150 ms. Results suggest that between 53.5%-97.7% of delay-based interoceptive individuals perceive heartbeats at a delay that does not correspond to the typical asynchronous or synchronous delays used to present tones on the 2AFC-HDT. These issues suggest that the 2AFC-HDT (or other measures that make assumptions about perceived timing of heartbeats) should not be used to measure cardiac interoceptive accuracy, or cardiac interoceptive insight (also known as awareness or metacognition).