MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuchi.2024.101560

Медицинская библиотека · Neuro-Chirurgie · 2024

Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique.

Chevillotte Thomas, Darnis Alice, Grobost Pierre, Palmano Marine, Guedj Jérémie, Silvestre Clément

СтатьяКлинический случайПеревод в очереди

Аннотация

BACKGROUND

In case of high sacral slope, anterior lumbosacral fusions can be performed by retroperitoneal or transperitoneal approach using a reversed Bohlman technique with an autologous corticocancellous fibular graft. The use of a trans-lumbosacral implant can avoid the iatrogenic effects but currently, there is no implant specifically designed for this fusion technique. Could the IFUSE implant from SI BONE replace a fibular graft to avoiding the iatrogenic effect induced by sampling during a Reverse Bohlman technique?

PATIENTS AND

METHODS

We present the case of a 38-year-old woman with L5S1 interbody pseudarthrosis after posterior fixation for grade 2 L5-S1 spondylolisthesis with isthmic lysis of L5, and that of a 69-year-old woman who underwent a posterior T4 fusion to the pelvis for degenerative scoliosis. Both required a trans-lumbosacral instrumented fusion via an anterior approach using the reverse Bohlman technique. Surgical technique was described.

RESULTS

There were no perioperative or postoperative complications. At 6 months, the patients reported a decrease in lumbar and radicular symptomatology. There were no infectious, neurological or vascular complications. CT-scans confirmed the good position and stability of the IFUSE implant.

DISCUSSION: We present an innovative interbody grafting technique adapted to spines with high pelvic incidence. The surgical technique is safe, minimally invasive, and reduces surgical iatrogeny. The short and medium-term results are positive but require longer-term follow-up and a larger cohort.

Для цитирования: Chevillotte Thomas, Darnis Alice, Grobost Pierre, Palmano Marine, Guedj Jérémie, Silvestre Clément. Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique.. Neuro-Chirurgie. 2024. DOI: 10.1016/j.neuchi.2024.101560.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.