DOI 10.1016/j.injury.2026.113224
Letter to the editor regarding "Comparison of the therapeutic effects of modified 15-mm incision minimally invasive approach with the conventional approach in the treatment of AO 23-B3 distal radius fractures".
Аннотация
This letter comments on Liu et al.'s study comparing a modified 15 mm mini-incision volar plating approach to conventional ORIF for AO 23-B3 distal radius fractures. While endorsing the reported cosmetic and recovery benefits of MIPO, we highlight the need for longitudinal functional data during early rehabilitation and detailed classification of postoperative complications. Addressing these gaps would enhance the understanding of the early recovery trajectory and safety profile of this minimally invasive technique.