m+Medelevator.RU
← Поиск публикаций
Blood · 2025

Rapid ADAMTS13 activity assays for thrombotic thrombocytopenic purpura: a systematic review and meta-analysis.

СтатьяСистематический обзорМетаанализНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Deshpande Saarang R, Tarawneh Hemza, Deitelzweig Chloe, Tong Jiayi, Zhou Ting, Chen Yong, Cuker Adam

Аннотация

Thrombotic thrombocytopenic purpura (TTP) is a rare, potentially fatal thrombotic microangiopathy caused by severe ADAMTS13 (a disintegrin and metalloproteinase with thrombospondin motif 13) deficiency. Prompt treatment improves survival; however, reference standard enzyme-linked immunosorbent assay and FRETS-VWF73 ADAMTS13 activity assays have long turnaround times (TATs) that necessitate empiric treatment of many patients who ultimately are found not to have TTP. Rapid assays with analytical TATs <1 hour have recently become available. We conducted a systematic review and meta-analysis of the performance characteristics of rapid assays relative to reference standard assays for ADAMTS13 activity for patients with suspected or confirmed TTP. Nineteen studies representing 3 rapid ADAMTS13 assays and 4207 patient samples were included. The HemosIL AcuStar chemiluminescence immunoassay (CLIA) demonstrated high sensitivity (0.98; 95% confidence interval [CI], 0.94-1.00), specificity (0.99; 95% CI, 0.97-1.00), and positive (PPV) (0.96; 95% CI, 0.90-0.98) and negative predictive values (NPV) (0.99; 95% CI, 0.99-1.00). The Technofluor fluorescence resonance energy transfer (FRET) and Technoscreen assays had sensitivity of 0.93 (95% CI, 0.86-0.96) and 0.98 (95% CI, 0.42-1.00), specificity of 0.98 (95% CI, 0.95-0.99) and 0.87 (95% CI, 0.76-0.94), PPV of 0.97 (95% CI, 0.85-1.00) and 0.71 (95% CI, 0.59-0.80), and NPV of 0.96 (95% CI, 0.93-0.98) and 0.99 (95% CI, 0.72-1.00), respectively. The proportion of discrepant results (relative to reference standard assays) was 0.04 (95% CI, 0.03-0.05) for HemosIL AcuStar, 0.04 (95% CI, 0.02-0.06) for Technofluor FRET, and 0.11 (95% CI, 0.07-0.16) for the Technoscreen assay. With rapid TAT and high sensitivity, the HemosIL AcuStar CLIA seems able to reliably avert empiric plasma exchange, corticosteroids, and caplacizumab in patients without TTP.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты