MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ons/opy170

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2019

A Novel Technique for Prevention of Subarachnoid-Pleural Fistula After Incidental Durotomy During Transthoracic Spinal Surgery.

He Kevin D, Rymarczuk George N, Clark Shannon W, Gillick John L, Vahedi Payman, Sharan Ashwini D

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Subarachnoid-pleural fistulas (SPFs) are rare but significant complications of transthoracic spinal surgery. Whether noted intraoperatively or in the postoperative period, SPF requires implementation of aggressive management, with consideration given to direct surgical repair. Additionally, the physical constraints of the thoracic cavity often hinder direct SPF repair.

OBJECTIVE

To present a novel operative technique that can be used to easily and quickly address incidental durotomy incurred during transthoracic spinal surgery while working within the confines of the thorax.

METHODS

Surgical hemostatic clips were used to affix a patch-graft of dural substitute to the parietal pleura surrounding the site of a transthoracic spinal decompression in which an incidental durotomy was incurred. The patch-graft was augmented with the application of biological glue and was successful in preventing symptomatic SPF.

RESULTS

The use of surgical clips to affix a patch graft is a quick, easy, and effective means of addressing an incidental durotomy during thoracotomy and preventing SPF. The clip applier is significantly easier to maneuver within the narrow working channel of the thorax than are instruments used during direct repair.

CONCLUSION

Preventing SPF can be challenging. The physical constraints of the thoracic cavity make water-tight repair difficult and time-consuming, particularly when the morphology of the dural tear prevents primary apposition of the defect. The authors present a novel technique of preventing development of SPF using hemostatic clips to simply and quickly affix suturable dural substitute to the parietal pleura overlying the site of an incidental durotomy.

Для цитирования: He Kevin D, Rymarczuk George N, Clark Shannon W, Gillick John L, Vahedi Payman, Sharan Ashwini D. A Novel Technique for Prevention of Subarachnoid-Pleural Fistula After Incidental Durotomy During Transthoracic Spinal Surgery.. Operative neurosurgery (Hagerstown, Md.). 2019. DOI: 10.1093/ons/opy170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.