DOI 10.1097/brs.0000000000005091
In vivo Assessment of AMP2, a Novel Ceramic-Binding BMP-2, in Ovine Lumbar Interbody Fusion.
Аннотация
STUDY
DESIGN
Assessment of bone formation in an ovine interbody fusion study.
OBJECTIVE
To compare OsteoAdapt SP, which consists of AMP-2, a modified variant of recombinant human bone morphogenetic protein (rhBMP-2) bound to a tricalcium phosphate-containing carrier, to autologous iliac crest bone graft (ICBG) in a lumbar interbody fusion model.
SUMMARY OF BACKGROUND DATA: Treatment of lumbar disk degeneration often involves spinal fusion to reduce pain and motion at the affected spinal segment by insertion of a cage containing bone graft material. Three graft materials were compared in this study-ICBG and OsteoAdapt SP (low or high dose).
METHODS
The sheep underwent lateral lumbar fusion surgery with PEEK or Titanium interbody cages packed with OsteoAdapt SP (low or high dose) or ICBG. Outcomes were evaluated at 8-, 16- and 26- weeks. Newly formed bone quality, bone mineralization, and fusion were assessed by manual palpation, qualitative and semi-quantitative histopathology, histomorphometry, computed tomography (CT), and micro-CT (mCT) analysis.
RESULTS
OsteoAdapt SP was implanted into 43 animals and ICBG into 21 animals (L3-L4). No group showed evidence of systemic toxicity by multiple assessments. All levels were fused by manual palpation at 26 weeks. Serial CT scans showed increasing fusion scores over time. Both doses of OsteoAdapt SP resulted in robust new bone formation and progression of fusion in the interbody cage. Range of motion tests for treatment groups was lower compared with ICBG at 8- and 16 weeks. Similarly, histology at eight weeks demonstrated more robust new bone formation for both OsteoAdapt SP groups compared to autograft.
CONCLUSION
We have demonstrated the preclinical safety and efficacy of OsteoAdapt SP in a clinically relevant large animal model, supporting faster and more robust new bone formation within the interbody cage, comparable to or better than the gold standard, ICBG, in all measures.