m+Medelevator.RU
← Поиск публикаций
World neurosurgery · 2024

Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

De Biase Gaetano, Akinduro Oluwaseun O, Garcia Diogo, Bojaxhi Elird, Buchanan Ian A, Gruenbaum Shaun E, Forcht Dagi Teodoro, Quinones-Hinojosa Alfredo, Abode-Iyamah Kingsley

Аннотация

BACKGROUND: We describe our protocol and outcomes of awake robotic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) under spinal anesthesia.

METHODS: We conducted a prospective study of 10 consecutive patients undergoing awake robotic single-level MIS-TLIF with the Mazor X robot. We prospectively collected patient-reported outcomes (back and leg pain visual analog scale and Oswestry Disability Index) preoperatively at 1-month and 1-year follow-ups and assessed fusion and screw placement accuracy with a 1-year computed tomography (CT) scan.

RESULTS: Median age was 61 years (interquartile range [IQR] = 57.7-66). Median body mass index was 27 kg/m2. No intraoperative complications were reported. Most (9/10) patients were discharged home, and 50% discharged on the day of surgery. Median length of stay was 16.5 hours (IQR = 5-35.5). Median follow-up was 12.5 months (IQR = 12-13.5), with 9 patients having at least 12-month follow-up, with CT scans documenting good screw placement (Gertzbein-Robbins grade A) and solid bony fusion. Median preoperative back pain visual analog scale score was 7.8 (IQR = 6.9-8) versus 1.5 (IQR = 0-3.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-1) at 1-year follow-up, P < 0.01; median preoperative leg pain 8 (IQR = 7.4-8) versus 0 (IQR = 0-1.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-2) at 1-year follow-up, P < 0.01; median preoperative Oswestry Disability Index 47.5 (IQR = 27.8-57.5) versus 4 (IQR = 0-16) at 1-month postoperation, P < 0.01, and 0 (IQR = 0-7) at 1-year follow-up, P < 0.01. Median preoperative disk height of the index level was 8 mm (IQR = 2.4-9.5) versus 11.4 mm (IQR = 9.2-11.2) postoperatively,P < 0.01. Median preoperative lordosis of the index level was 5 degrees (IQR = 3.4-8.5) versus 10.1 degrees (7.3-12.2) postoperatively, P < 0.01.

CONCLUSIONS: Our study showed significant improvement in patient-reported outcomes at 1-month and 1-year follow-ups after awake robotic MIS-TLIF, as well as solid bony fusion on CT scans.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты