Volumetric analysis of mandibular lesions with SPECT/CT: a pilot clinical study of maximum standardized uptake value.

Minami Yoshiyuki, Ogawa Ruri, Ogura Ichiro

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study was designed to investigate mandibular lesions using volumetric analysis with bone single-photon emission computed tomography/computed tomography (SPECT/CT).

MATERIAL AND

METHODS

Eight patients with mandibular lesions underwent SPECT/CT scan acquisition 4 hours after injection of Tc-99m hydroxymethylene diphosphonate (HMDP). Regarding volumetric analysis, maximum standar-dized uptake value (SUV) was obtained using software and a workstation (Q.Volumetrix MI and GEniE-Xeleris 4 DR, respectively). The localization and size of the volume of interest (VOI) can be drawn over the lesion, mesial, distal, and opposite side as normal using the CT, SPECT, and SPECT/CT transaxials, coronals, and sagittals as the anatomical reference. Q.Volumetrix MI can analyse SUV of lesions by organ segmentation using optional pan and zoom imaging. Then, the dosimetry software provided multiple quantitative data for a given VOI. Statistical analyses for the maximum SUV were performed by Mann-Whitney U test. A p-value lower than 0.05 was considered as statistically significant.

RESULTS

Maximum SUVs for medication-related osteonecrosis of the jaw (n = 4, 25.4 ± 4.9), chronic osteomyelitis (n = 3, 14.6 ± 3.1), and squamous cell carcinoma (n = 1, 31.7) were significantly higher than those of the opposite side as normal mandible (3.8 ± 0.7, 4.6 ± 1.8, and 7.4, respectively; p = 0.000).

CONCLUSIONS

Volumetric analysis with SPECT/CT could be useful for the evaluation of mandibular lesions, such as detecting and surgical planning.

Для цитирования: Minami Yoshiyuki, Ogawa Ruri, Ogura Ichiro. Volumetric analysis of mandibular lesions with SPECT/CT: a pilot clinical study of maximum standardized uptake value.. Polish journal of radiology. 2022. DOI: 10.5114/pjr.2022.117569.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.