MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2020.01.012

Медицинская библиотека · Thrombosis research · 2020

Hyper-coagulability in obese patients accurately identified by combinations of global coagulation assay parameters.

Bertaggia Calderara Debora, Aliotta Alessandro, Zermatten Maxime G, Kröll Dino, Stirnimann Guido, Alberio Lorenzo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Routine laboratory methods are insensitive to hyper-coagulation, which may be detected by global hemostasis tests. Calibrated Automated Thrombogram (CAT) is a gold standard method to measure thrombin generation and coagulation potential. Thrombodynamics (TD) is a new global assay that monitors the spatio-temporal propagation of blood coagulation, separating initiation from amplification/propagation phases of coagulation and visualizing fibrin clot formation.

AIM: We investigated whether CAT and/or TD can identify hyper- and hypo-coagulable states in patients with well-characterized phenotypes and which parameters could be used as potential predictors of thrombotic risk.

METHODS

Blood was collected from: (1) forty healthy volunteers; (2) twelve obese patients scheduled for bariatric surgery (BMI ≥ 35 kg/m2); (3) nine patients under therapy with vitamin K-antagonists (median INR 2.7); (4) eight patients treated with low molecular weight heparins (anti-Xa activity between 0.5 and 0.7 U anti-Xa/ml); (5) ten patients with hemophilia A or B. Tissue factor induced thrombin generation was measured with CAT. Propagation of thrombin generation and clot growth from a tissue factor coated surface were monitored with TD.

RESULTS

Thrombin generation and fibrin clot formation parameters were significantly higher in obese patients compared to healthy volunteers and anticoagulated or hemophilic patients. ROC analysis of combined CAT or CAT/TD parameters (integrating thrombin generation and fibrin clot formation) demonstrated an excellent accuracy in detecting hyper-coagulability.

CONCLUSION

Combinations of CAT assay parameters and of parameters of thrombin generation burst with final fibrin clot properties allow recognizing accurately hyper-coagulable plasma and may represent predictive markers for thrombotic events.

Для цитирования: Bertaggia Calderara Debora, Aliotta Alessandro, Zermatten Maxime G, Kröll Dino, Stirnimann Guido, Alberio Lorenzo. Hyper-coagulability in obese patients accurately identified by combinations of global coagulation assay parameters.. Thrombosis research. 2020. DOI: 10.1016/j.thromres.2020.01.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.