BACKGROUND

The aim of this study was to compare the biomechanical characteristics between bilateral and unilateral lumbo-iliac fixation in unilateral comminuted sacral fractures (USF) by finite element analysis.

METHODS

A 3-dimensional finite element model of unilateral sacral fractures was simulated. Three kinds of implants were instrumented into the model, including the unilateral lumbopelvic fixation (ULF), bilateral lumbopelvic fixation (BLF), and unilateral iliac fixation with bilateral lumbar pedicle screws (UBF). Loads of compression and rotation were distributed to the superior endplate of L3. To evaluate the biomechanical properties, the construct stiffness, the micromotion of the fractures, the stress distribution of implants, and the balance of hemilumbar vertebra are recorded and analyzed.

RESULTS

The highest construct stiffness was provided by BLF. In BLF model, the displacement between iliums was only 0.009 mm (compressional) and 0.001 mm (rotational), which was less than that under normal condition (0.02 mm). The maximum von Misses stress of implants appeared on the UBF. By using unilateral fixation, the L4 endured obvious imbalance on bilateral hemivertebra. A marked difference was exposed in BLF and UBF models, and the equilibrium of stress and activity was shown.

CONCLUSION

From the finite element view, the stability of ULF is insufficient to reconstruct the posterior pelvic ring. Furthermore, the unilateral fixation may lead to imbalance of lumbar vertebra and pelvis. On the contrary, the BLF can provide satisfied stability and lumbar balance.

Для цитирования: Song Wenhao, Zhou Dongsheng, He Yu. The biomechanical advantages of bilateral lumbo-iliac fixation in unilateral comminuted sacral fractures without sacroiliac screw safe channel: A finite element analysis.. Medicine. 2016. DOI: 10.1097/md.0000000000005026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.