MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/ijn.s460339

Медицинская библиотека · International journal of nanomedicine · 2024

High Strength and Shape Memory Spinal Fusion Device for Minimally Invasive Interbody Fusions.

Liu Min, Liu Bo, Liu Ziyang, Yang Zhen, Webster Thomas J, Zhou Huan, Yang Lei

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Lumbar interbody fusion is widely employed for both acute and chronic spinal diseases interventions. However, large incision created during interbody cage implantation may adversely impair spinal tissue and influence postoperative recovery. The aim of this study was to design a shape memory interbody fusion device suitable for small incision implantation.

METHODS

In this study, we designed and fabricated an intervertebral fusion cage that utilizes near-infrared (NIR) light-responsive shape memory characteristics. This cage was composed of bisphenol A diglycidyl ether, polyether amine D-230, decylamine and iron oxide nanoparticles. A self-hardening calcium phosphate-starch cement (CSC) was injected internally through the injection channel of the cage for healing outcome improvement.

RESULTS

The size of the interbody cage is reduced from 22 mm to 8.8 mm to minimize the incision size. Subsequent NIR light irradiation prompted a swift recovery of the cage shape within 5 min at the lesion site. The biocompatibility of the shape memory composite was validated through in vitro MC3T3-E1 cell (osteoblast-like cells) adhesion and proliferation assays and subcutaneous implantation experiments in rats. CSC was injected into the cage, and the relevant results revealed that CSC is uniformly dispersed within the internal space, along with the cage compressive strength increasing from 12 to 20 MPa.

CONCLUSION

The results from this study thus demonstrated that this integrated approach of using a minimally invasive NIR shape memory spinal fusion cage with CSC has potential for lumbar interbody fusion.

Для цитирования: Liu Min, Liu Bo, Liu Ziyang, Yang Zhen, Webster Thomas J, Zhou Huan, Yang Lei. High Strength and Shape Memory Spinal Fusion Device for Minimally Invasive Interbody Fusions.. International journal of nanomedicine. 2024. DOI: 10.2147/ijn.s460339.