m+Medelevator.RU
← Поиск публикаций
Analytical chemistry · 2026

Multifunctional CoFcMOF Nanozyme Facilitates a Self-Validating Triple-Modal Immunosensor for CRP in Serum and Synovial Fluid.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Jingshu, Zhong Yuee, Liu Jing, Wang Xuan, Tang Jianru, Zhu Xiaohua, Huang Shu, Zhang Youyu, Liu Meiling

Аннотация

Accurate quantification of C-reactive protein (CRP) in serum and synovial fluid is critical for diagnosing and monitoring localized inflammatory arthritis, but it remains challenging due to the complexity of the matrix and the lack of robust and sensitive assays. To overcome this critical challenge, a novel self-validating triple-modal immunosensing platform was developed based on a rationally designed multifunctional cobalt-ferrocene metal-organic framework (CoFcMOF) nanozyme, which ensures robust detection reliability through a synergistic signal fusion mechanism. The innovation lies in the "three-in-one" nanolabel of CoFcMOF that concurrently serves as a peroxidase (POD) mimic for colorimetric readout, an efficient quencher for the electrochemiluminescence (ECL) of carboxylated graphitic carbon nitride (C-g-C3N4), and a bioconjugation tag that amplifies the electrochemical impedance spectroscopy (EIS) signal upon immunocomplex formation. Critically, all three mechanistically distinct yet intrinsically linked signaling pathways are intrinsically triggered by a single biorecognition event, enabling real-time and built-in cross-validation. This cooperative design affords exceptional sensitivity, with detection limits of 0.075 pg/mL (ECL), 0.095 pg/mL (EIS), and 0.29 pg/mL (colorimetry) for CRP, while demonstrating outstanding anti-interference performance in serum and synovial fluid samples. Beyond providing a precise and reliable method for CRP analysis, this work establishes a new biosensing paradigm that utilizes rationally engineered multifunctional materials for inherently self-validating, multimechanism detection, paving the way for next-generation diagnostic systems capable of high-accuracy analysis in complex real-world samples.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты