Design and radiological confirmation of 3-column cortical bone trajectory in the lumbar spine.

Wang Jia-Qi, Zhang Ren-Jie, Zhou Lu-Ping, Jia Chong-Yu, Zhang Bo, Sheng Rui, Fang Shu, Shen Cai-Liang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to design a novel lumbar cortical bone trajectory (CBT) penetrating the anterior, middle, and posterior vertebral area using imaging; measure the relevant parameters to find theoretical parameters and screw placement possibilities; and investigate the optimal implantation trajectory of the CBT in patients with osteoporosis.

METHODS

Three types of CBTs with appropriate lengths were selected to simulate screw placement using Mimics software. These CBTs were classified as the leading tip of the trajectory pointing to the posterior quarter area (original CBT [CBT-O]) and middle (novel CBT A [CBT-A]) and anterior quarter (novel CBT B [CBT-B]) of the superior endplate. The authors then measured the maximum screw diameter (MSD) and length (MSL), cephalad (CA) and lateral (LA) angles, and bone mineral density (Hounsfield unit [HU] values) of the planned novel 3-column CBT screw placements. The differences in the parameters of the novel CBTs, the percentages of successfully planned CBT screws, and the factors that influenced the successful planning of 3-column CBT screws were analyzed.

RESULTS

Three-column CBT screws were successfully designed in all segments of the lumbar spine. The success rate of the 3-column CBT planned screws was 72.25% (83.25% for CBT-A and 61.25% for CBT-B). From the CBT-O type, to the CBT-A type, to the CBT-B type, the LA, CA, and MSD of the novel CBT screws decreased with increasing trajectory length. The HU values of the three types of trajectories were all significantly higher than that of the traditional pedicle screw trajectory (p < 0.001). The main factor affecting successful planning of the 3-column CBT screw was pedicle width.

CONCLUSIONS

Moderating adjustment of the original screw parameters by reducing LAs and CAs to penetrate the anterior, middle, and posterior columns of the vertebral body using the 3-column CBT screw is feasible, especially in the lower lumbar spine.

Для цитирования: Wang Jia-Qi, Zhang Ren-Jie, Zhou Lu-Ping, Jia Chong-Yu, Zhang Bo, Sheng Rui, Fang Shu, Shen Cai-Liang. Design and radiological confirmation of 3-column cortical bone trajectory in the lumbar spine.. Journal of neurosurgery. Spine. 2024. DOI: 10.3171/2024.2.spine231208.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.