MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.118735

Медицинская библиотека · Biosensors & bioelectronics · 2026

Cube-track encoded dual-mode ECL/SERS biosensor for ultrasensitive NF-κB p50 detection via transcription-DSN cascade.

Guo Pengwei, Ren Haozhen, Pan Jiran, Tao Shouwen, Nong Qingxiao, Gong Yuanxun, Ma Yanfei, Wei Jihua, Tang Qianli, Zhang Kai, Liao Xianjiu

СтатьяПеревод в очереди

Аннотация

Accurate quantification of trace transcription factors remains challenging because protein-nucleic acid recognition must be translated into a robust signal while resisting matrix interference and instrumental drift. Here, we report a dual-mode ratiometric biosensor for ultrasensitive detection of NF-κB p50 by integrating a CsPbBr3@PDA@AuNPs/MXene (PAM) hybrid transducer with a programmable nucleic-acid cascade and a wireframe DNA cube-track interface. In this design, NF-κB p50 initiates a DNA regulatory circuit that generates amplified nucleic-acid outputs through T7 transcription, which subsequently drive DSN-assisted cleavage of ferrocene (Fc) tags positioned on cube tracks at the electrode surface. This target-programmed interfacial Fc depletion simultaneously restores the PAM electrochemiluminescence (ECL-on) and attenuates the Fc Raman signal (SERS-off), enabling a self-calibrated ratiometric readout. The biosensor exhibits a wide working range from 0.1 to 1000 pM and an estimated limit of detection of 2.3 × 10-3 pM based on the 3σ criterion, further supported by additional low-concentration experimental verification. Selectivity studies against closely related NF-κB family proteins and high-concentration non-specific proteins confirm strong target/non-target discrimination, while repeatability, electrode-to-electrode reproducibility, stability assays, and spike-recovery experiments in diluted MCF-7 cell lysate demonstrate reliable operation in complex samples. This work establishes a general protein-to-nucleic-acid information conversion strategy coupled with cube-track encoded dual-mode transduction, providing a practical route for sensitive and robust transcription-factor analysis and offering potential for further miniaturization and point-of-care applications.

Для цитирования: Guo Pengwei, Ren Haozhen, Pan Jiran, Tao Shouwen, Nong Qingxiao, Gong Yuanxun, Ma Yanfei, Wei Jihua, Tang Qianli, Zhang Kai, Liao Xianjiu. Cube-track encoded dual-mode ECL/SERS biosensor for ultrasensitive NF-κB p50 detection via transcription-DSN cascade.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.118735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.