MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2025.1594207

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2025

Biomechanical comparison of suspensory traction and axial traction in preoperative correction of cervical kyphosis: a finite element study.

Chen Hongyu, Wu Tianchi, Pan Shengfa, Zhang Li, Zhao Yanbin, Chen Xin, Sun Yu, Lu William W, Zhou Feifei

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the biomechanical characteristics of axial traction and suspensory traction in the process of preoperative correction of cervical kyphosis.

METHODS

An intact three-dimensional finite element digital model of C2-T2 with cervical kyphosis was established. The head gravity and moment were applied to the finite element model to simulate the force of skull traction and the force of suspensory traction. The changes of cervical kyphotic angle, the length of cervical spinal canal and the stress distribution of each vertebral body were analyzed under two traction modes.

RESULTS

The kyphotic angles of the kyphotic segments were reduced by both tractions. The C2-C5 kyphotic angle was 41° before traction, and decreased to 32° and 26° after axial traction and suspensory traction, respectively. The length of C3-C7 cervical spinal canal was 61.3 mm before traction. After axial traction, the length of C3-C7 cervical spinal canal increased to 61.8 mm; after suspensory traction, it decreased to 59. 6 mm. The high stress area of each vertebral body was located in the anterior longitudinal ligament attachment area of the vertebral body during both two kinds of traction. The maximum Mises stress of C2-C7 vertebral body in suspensory traction is generally small relative to axial traction.

CONCLUSION

Compared with axial traction, suspensory traction has better kyphotic corrective effect, while reduces the length of the cervical spinal canal and the stress on the cervical vertebral body, which decreases the possibility of nerve damage and iatrogenic fracture during traction from a biomechanical point of view.

Для цитирования: Chen Hongyu, Wu Tianchi, Pan Shengfa, Zhang Li, Zhao Yanbin, Chen Xin, Sun Yu, Lu William W, Zhou Feifei. Biomechanical comparison of suspensory traction and axial traction in preoperative correction of cervical kyphosis: a finite element study.. Frontiers in bioengineering and biotechnology. 2025. DOI: 10.3389/fbioe.2025.1594207.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.